You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Creating and Customizing Test Configurations Locally

To create a custom configuration locally, you need to copy a selected built-in configuration to the User directory, and then customize the duplicated configuration.

  1. Click  Parasoft in the menu bar and choose Options (Visual Studio) or Preferences (Eclipse). Then select Configuration.

  2. Right-click the test configuration you want to duplicate, then choose Duplicate Locally

    The configuration will be added to the User directory and nested in a parent directory matching the source.

  3. Right-click the duplicate configuration and choose Edit to open the Test Configuration Editor in you browser.

    NOTE: The Test Configuration Editor is handled by a separate web server process and may be blocked if a strict firewall is installed on your machine. In such case, allow the process to run when prompted.


    Choosing Edit as text opens a textual representation of the configuration in a simple configuration editor (deprecated).
         

  4. Click a tab to access a group of related test configuration settings. For additional information about test configuration settings, mouse over an information icon ("i") next to a configuration setting. The following tabs are available:

Scope Tab

The Scope tab contains a set of filters that you can configure to define the parts of the code that the test configuration should cover. You must connect the C/C++test  to source control in order to collect scope information. Click Save to preserve any changes you make on this tab.

Time Filters

Expand the Time filters settings to set time-based filters at the file or line level. The time filters enable you to restrict the scope of analysis to a specific date range or period. If the scope.scontrol setting is set to true and the source control settings for C/C++test  are configured, the modification time is set from the source control history. If scope.local is set to true, then the modification time is set form the file system of the machine running analysis. See Scope and Authorship Settings for details.

You can configure the following settings:

File-level settings

Check all files

Default. Enable this option to include all files in the scope of the analysis the user has access to.

Check locally-modified files

Enable this option to only check locally modified files.

For this option to take effect, ensure that connection to your source control system is properly configured and authorship is computed based on data from that source control system. See the prerequisites in Defining Additional Scope Filters.

Check files modified within a date rangeEnable this option and specify a date range to include in the scope. Files that were modified or added within the specified range will be checked.
Check files modified within last n daysEnable this option and specify the number of days to include in the scope. Files that were modified or added within the specified number of days will be checked.
Check files modified between the current working branch and

Enable this option to only analyze files that are different between the current working branch and the reference branch. This allows you to speed up analysis by excluding unchanged files from the test scope.

You need to configure one of the following options to specify which branch is used as reference:

  • main integration stream - The current working branch is compared with the main stream of development, such as "master", "trunk", etc.
  • custom reference branch/revision- Allows you to manually specify the branch or revision with which the current branch is compared.

For this option to take effect, ensure that connection to your source control system is properly configured and authorship is computed based on data from that source control system. See the prerequisites in Defining Additional Scope Filters.

This option is only supported for Git SCM.

(info) If a scope filter is configured in both Test Configuration Editor and the .properties file, the configuration specified in the .properties file will override the settings configured in the GUI. See Defining Additional Scope Filters for details.

Line-level Settings

Check all lines

Default. Enable this option to include all lines of code in the scope of the analysis the user has access to.

Check locally-modified lines

Enable this option to only check locally modified lines.

For this option to take effect, ensure that connection to your source control system is properly configured and authorship is computed based on data from that source control system. See Configuring Authorship and Connecting to Source Control.

Check lines modified sinceEnable this option and specify a cut-off date to include in the scope. Lines of code that were modified or added within the specified range will be checked.
Check lines modified witin last n daysEnable this option and specify the number of days to include in the scope. Lines of code that were modified or added within the specified number of days will be checked.

File Path Filters

Expand the File path filters section to specify file path patterns to include and/or exclude from analysis. Relative paths within a workspace/solution.

The following settings are available:

Accepted paths (wildcard)

Specify a comma-separated list of files to include. Wildcards are supported (e.g., *.cpp, *.java, *.cs).

Rejected paths (wildcard)

Specify a comma-separated list of files to exclude. Wildcards are supported (e.g., *.cpp, *.java, *.cs).

Expand the Advanced discloser triangle to use regular expressions to set the file path filters. The following settings are available:

Accepted paths (regex)

Specify a regular expression. Files that match the pattern will be included in the analysis.

Rejected paths (regex)

Specify a regular expression. Files that match the pattern will be excluded in the analysis.

File Content Filters

Expand the File content filters section to specify regular expressions that exclude specific types of files based on content, e.g., auto-generated files.

File filtering takes priority over code block filtering

A potential conflict may occur if you use both filter types at the same time.

Author Filters

Expand the Author filters section to limit the scope of analysis to specific authors. If the scope.scontrol setting is set to true and the source control settings are configured, then file authorship is taken from the source control system. If the scope.xmlmap is set to true and the XML map settings are configured, then files authorship is taken from the map. 

The following options are available:

Include only files owned by authorsEnable this option to only include files owned by the authors specified in the List of authors field.
Include only lines owned by authors

Enable this option to only include lines of code owned by the authors specified in the List of authors field.

List of authorsSpecify a comma-separated list of authors whose code should be analyzed.

File Size Filters

Expand the File size filters section to limit the scope of analysis based on file size.

Code Block Options

Expand the Code block options section to define specific blocks of code to include or exclude from the analysis.

File filtering takes priority over code block filtering

A potential conflict may occur if you use both filter types at the same time.

Include only lines in certain blocksEnable this option to include only the code defined by the Starting and Ending marker fields in the analysis.
Starting markerSpecify a regular expression to mark the start of the code block that should be analyzed.
Ending markerSpecify a regular expression to mark the beginning of the code block that should be analyzed.
Skip files without these markersEnable this option skip files that do not include patterns that match the Starting and Ending marker fields.

Static Analysis Tab

Click the Static Analysis tab to enable/disable the static analysis rules the configuration uses. This page shows all the supported rules. Click Save to preserve any changes you make on this tab.

Enabling Static Analysis

Enable or disable the Enable static analysis checkbox to enable/disable static and flow analysis.

Finding Rules

You can use the search bar to find a specific rule or rule category. You can also use the drop-down menu to filter by category and browse for a rule.



Enable the Show Enabled Only option to only show the enabled rules.

Enabling and Disabling Rules

Rules are grouped by category. Expand a category and enable the rule to use it in the test configuration. 

Click the Enable [number] of rule(s) or Disable [number] of rule(s) button to quickly enable or disable all rules in the configuration.

Viewing Rule Documentation

Click on a rule to open the documentation panel.

You can also open the rule documentation in new browser tab.

Click on the documentation icon to open all documentation for the enabled rules in a new browser tab.

Parameterizing Rules

If the rule can be configured, parameters can be set in the rule options panel. Click on a rule and click the Rule Parameters tab to configure the rule. The options available are specific to each rule.

Metrics Tab

Click the Metrics tab to enable/disable the metrics collected and calculated during analysis. Click Save to preserve any changes you make on this tab.

You can perform the following actions:

  • Enter a metric ID in the search field to locate a specific metric.
  • Enable the Show Enabled Only option to filter by enabled metrics.
  • Click Enable [n] metric(s) or Disable [n] metric(s) to enable or disable all metrics in the test configuration.
  • Enable/disable individual metrics.
  • Enable the Report static analysis violation when outside of acceptable ranges option to configure an upper and lower threshold for the metric. A flag icon will appear in the Enabled column if this option is enabled.
  • Click on a metric to view the documentation.

Unit Tests Tab

Click the Unit Tests tab to access controls for unit test execution and coverage data collection.

You can enable/disable the collection of unit test results and coverage analysis.

Static Analysis Settings Tab

Click the Static Settings Analysis tab allows you to configure your static analysis and flow-based analysis. Click Save to preserve any changes you make on this tab.

Advanced Settings

Expand the Advanced Settings section to configure the following options:

  • Set an upper limit on the number of violations that can be reported for each rule.
  • Enable or disable the Ignore suppressions option to specify if you want rule violations suppressed on the engine host to be reported. If enabled, all violations are reported, including suppressed violations. This option is disabled by default.

Flow Analysis Advanced Settings

Expand the Flow Analysis Advanced Settings section to configure settings related to performance, reporting verbosity, null-checking method parameterization, and resources checked. 

See Configuring Flow Analysis for details.

General Settings Tab

Click on the General Settings tab to view and edit the name and location of the test configuration. Click Save to preserve any changes you make on this tab.

(info) Enter a name in the Folder field to change the location of the test configuration. Entering the name of an existing folder moves the test configuration to that location in the test configuration tree. If the name you specify doesn't exist, a new folder will be created and the test configuration moved into it. You can also nest folders by placing a forward slash (/) between folder names.

Creating and Customizing Test Configurations on DTP

  1. Click  Parasoft in the menu bar and choose Options (Visual Studio) or Preferences (Eclipse).

     Then select Configuration.

  2. Right-click the Built-in or User test configuration you want to duplicate, then choose Duplicate on DTP.

    The configuration will be added to the DTP directory and uploaded to the DTP server (see Connecting to DTP

  3. Right-click the duplicate configuration and choose Open in DTP.

    If you are not logged in DTP, the DTP login page will open in a browser. Provide your credentials to log in.
    The Test Configuration page in DTP will open. 

  4. Open the list of test configurations. The duplicated test configuration will be available in the configurations lists.

     
  5. Click the duplicated test configuration to open the configuration interface. See the DTP documentation for details about how to customize test configurations on DTP.


  • No labels