Unconstrained mode (the mode enabled when Service Definition is set to None) lets you specify the URL as a literal string, which can be either a fixed value, parameterized value, or scripted value. In addition, the method to invoke can also be specified as a fixed value, parameterized value, or scripted value.  For details about For details about parameterizing values, see Parameterizing Tools with Data Source Values, Variables, and Extracted Values.For details about scripting values, see Extensibility and or Scripting Basics.

With fixed values, you can access data source values using ${var_name} syntax. You can also use the environment variables that you have specified. For details about environments, see  Configuring Virtualize Environments.

...

...

...

...

When specifying the payload, you can select input modes from the Input Mode drop-down list. The REST Client tool shares Input Mode options with other client tools. For more information on these shared options, see Message Tool and Responder Common Messaging Options.

For XML or JSON associated with a schema, the applicable form view will be automatically populated according to the values in the definition and editing will be restricted to ensure that the message complies with the specified schema. For instance, you will not be able to insert, delete, rename, copy, or paste tree nodes. 

...

Select the appropriate protocol from the Transport drop-down list, then configure its properties, which are described in the following sections:

Virtualize

Misc Tab

The following options are available in the Success Criteria tab of the REST Client tool:

  • Valid HTTP Response Codes: Allows you to customize the tool behavior so that it succeeds with HTTP response codes outside the 2xx range. Specify single codes and/or code ranges as a comma-separated list. For example, if you use "302, 500-599", a 302 code or any code in the 5xx range will be accepted.  If you're using a parameterized value, be sure that the value in the data source uses this same format (e.g., "302, 500-599").
  • Timeout after (milliseconds): Specifies the length of delay (in milliseconds) after which your FTP, telnet, or HTTP requests should time out. The Default setting corresponds to the timeout set in the Preferences panel. The Custom setting allows you to enter a timeout. A non-positive timeout value can be entered to specify an infinite timeout.

    • Fail the test on timeout: Select this option if you want the tool to fail on the specified timeout.
    • Pass the test only if a timeout occurred: Select this option to have the tool pass if the specified timeout occurs (i.e. the test does not finish execution within the specified time).
  • Outgoing Message Encoding: Choose Custom from the drop-down menu and choose an encoding for the outgoing message. The default is to use the encoding configured in the immediate parent test suite . You can also specify this option globally in the Parasoft Preferences Misc settings (see Additional Preference Settings Settings).