- By using the test configuration interface in DTP (see "Report Center> Test Configurations> Editing Test Configurations> Metrics Tab" in the Development Testing Platform DTP user manual for details).
- By editing the Metrics test configuration using the interface in an IDE (see Creating Custom Test Configurations).
- By manually editing the test configuration file:
1. Duplicate the built-in Metrics test configuration (
[INSTALL_DIR]/configs/builtin
) to the user configurations directory ([INSTALL_DIR]/configs/user
).2. Open the duplicate configuration in an editor and set the
[METRIC.ID].ThresholdEnabled
property totrue
.3. Configure the lower and upper boundaries in the
[METRIC.ID].Threshold
property according to the following format:[METRIC.ID].Threshold=l [lower boundary value] g [upper boundary value]
4. Save the test configuration and run the analysis using the custom metrics test configuration.
...